How to adjust the solar street lamp controller?
Leave a message
How to adjust the solar street lamp controller?
How to set the parameters of the solar street lamp controller? Each manufacturer's controller may be slightly different, but it's roughly the same!
■ Instructions for use:
Charging and overvoltage indicator: When the system is connected normally, and there is sunlight on the light panel, the charging indicator light (1) is green, indicating that the system charging circuit is normal; If the charging indicator (1) blinks green rapidly, it indicates that the system overvoltage. For details, see Troubleshooting. The charging process uses PWM mode, if the over-discharge action occurs, the charging must first reach the charging voltage, and maintain 10 minutes, and then reduce to the direct charging voltage, maintain 10 minutes, in order to activate the battery, avoid vulcanization crystallization, and finally reduce to the floating charging voltage, and maintain the floating charging voltage. If no discharge has occurred, there will be no lifting charge mode to prevent the battery from losing water. These automatic control processes will enable the battery to achieve the best charging effect and guarantee or extend its service life.
Battery status indicator: When the battery voltage is in the normal range, the status indicator (2) is green on; After the battery is fully charged, the status indicator blinks green and slowly. When the battery voltage is reduced to undervoltage, the status indicator turns orange; When the battery voltage continues to decrease to the overdischarge voltage, the status indicator (2) turns red, and the controller will automatically turn off the output to remind the user to replenish the power in time. When the battery voltage returns to the normal operating range, the output turn on action will be automatically enabled, and the status indicator (2) will turn green.
Load indicator: When the load is turned on, the load indicator (3) is steady on. If the load current exceeds 1.25 times the rated current of the controller for 60 seconds, or the load current exceeds 1.5 times the rated current of the controller for 5 seconds, the indicator (3) blinked red slowly, indicating overload, and the controller will turn off the output. When a short circuit fault occurs on the load or load side, the controller turns off the output immediately and indicator (3) blinks quickly. When the above phenomenon occurs, the user should carefully check the load connection, disconnect the faulty load, press the button once, and resume normal work after 30 seconds, or wait until the next day can work normally.
■ Working mode setting:
Setting method: Press the switch setting button for 5 seconds, the MODE display digital LED flashes, release the button, every time to convert a number, until the number displayed by the LED is on the number corresponding to the mode selected by the user from the table to stop the key, wait until the LED number does not blink to complete the setting. Each time the button is pressed, the LED lights up digitally and the set value can be observed.
Pure light control "0" mode: when there is no sunlight, the light intensity drops to the starting point, the controller delays 10 minutes to confirm the start signal, turn on the load, the load starts to work; When there is sunlight, the light intensity rises to the starting point, the controller delays 10 minutes to confirm the output signal is closed, and the output is closed, and the load stops working.
Optical control + delay mode (" 1 "-" 9 ", "0." - "5.") : The startup process is the same as before. When the load reaches the set time, the load is shut down. The time setting is shown in the following table. Light control is preferred.
General controller mode "6." : This mode only cancels the light control, time control function, output delay and related functions, and retains all other functions, which is used as a general general controller.
Debug mode "7." : Used for system debugging, the same as the pure optical control mode, only cancel the 10min delay to judge the optical signal control output, and retain all other functions. When there is an optical signal, the load is switched on, and the no light signal is turned off the load, which is convenient to check the correctness of the installation of the system during installation and debugging.
Output mode description: When the LED display mode is set, the display number is pure DC DC output without a decimal point, that is, "0" to "9" and "0." to "5." mode. If the number does not have a decimal point, that is, "0" to "9", the decimal point of the digital tube is not bright.
■ Working mode setting table: (Note: When the LED digital with decimal point mode is selected, the decimal point of the digital tube is long bright, which has no effect on the overall performance of the controller, and is only used for differentiation)
5, load connection, the load connection is connected to the load output terminal on the controller, pay attention to the +, - pole, do not reverse connection, so as not to burn the electrical appliance.
How to debug solar street lamp controller?
Setting method:
Press the key for more than 3s and the nixie tube starts to blink, the system enters the adjustment mode, release the key, every time you press the key, the nixie tube number will be changed by a number, until the number displayed on the nixie tube matches the number corresponding to the mode selected by the user from the table, and the nixie tube stops blinking or presses the key again for more than 3s to complete the setting. (Attached is the modulation schedule)
Mode introduction
Pure light control (0) : when there is no sunlight, the light intensity drops to the starting point, the controller delays 10 minutes to confirm the start signal, and opens the load according to the set parameters, and the load starts to work; When there is sunlight, the light intensity rises to the starting point, the controller delays 10 minutes to confirm the shutdown signal and then closes the output, and the load stops working.
Light control + time control (1 ~ 4 ·) : The starting process is the same as pure light control, when the load works to the set time, it will automatically shut down, set time 1 ~ 14 hours.
Manual mode (5 ·) : In this mode, the user can control the load on and off by pressing the button, regardless of whether it is day or night. This mode is used for some special load situations or debugging
Debugging mode (6 ·) : used for system debugging, the load is turned off when there is an optical signal, and the load is turned on when there is no light signal, which is convenient to check the correctness of the system installation during installation and debugging.
Normally on mode (7 ·) : The power-on load remains in the output state. This mode is suitable for loads that require 24-hour power supply.
Although the manufacturers show slightly different, but the method is the same, as long as you set against your instructions