Several common failures of solar garden lights
Leave a message
Solar garden lights are now more common lighting tools, often used in residential areas, parks and other venues. Installed solar yard lights should be maintained regularly to avoid some common failures. Solar garden lights, whether it is an old colloidal battery power supply or the current popular lithium battery integrated power supply, the main core source, solar modules, batteries, and controllers are composed of four parts, as long as the four parts are checked one by one to solve the fault.
1. The light source is faulty. Man-made or natural reasons may lead to the damage of the light source, resulting in the normal lighting of solar street lights, sometimes there will be switches, flickers and so on. If the user does not understand, it is best to replace the light source directly. If the user has a little understanding, you can open the lamp shell, find the aluminum plate of the light source, and use a multimeter and adjustable power supply to determine whether the lamp bead is burned out, damaged, or other circuit problems for further treatment. If the circuit is damaged, you can find a way to connect the circuit, if the lamp bead is damaged, you need to replace the lamp bead.
2. The solar module is faulty. During the day when the sun is good, when the solar panel is not loaded, use a multimeter to measure its voltage. Generally, the operating voltage of the system is 12v, which is higher than 12v in normal cases. The battery can only be charged when the voltage is higher than 12V. If it is lower than 12V, the battery cannot be charged, indicating that the solar street light system cannot work or the working time is not enough, resulting in the solar street light is not bright. Maintenance method: There are generally two problems, the problem of the component lead box, and the problem of the component itself. Let's break it up. 1, the component itself problem: the user should not fix this problem. There are defects in the components when they leave the factory, such as insufficient working voltage, insufficient power, etc., which is to say that they cannot be charged for a day. This is a direct replacement for the new. 2, lead box problem: on the premise of confirming that there is no problem with the components, it may be that the wiring in the lead box is loose, or the diode of the lead box is connected backwards. Handling is also simple, tighten the wiring and subtract the diode (low power components only).
3. Battery part. Battery quality varies. In actual use, there is often a lack of power leading to the light off. Use a multimeter to test whether the battery voltage is lower than 9V, you can directly confirm that the battery is out of power. Maintenance method: If the battery is not used for a long time, you can consider disassembling the machine. Use an external charger to charge the battery once (be careful to choose the right charger). If it still does not work, it is recommended to replace it directly, this thing is not worth repairing.
The controller part. The controller is the core part of the solar energy system, which controls the normal operation of the entire solar energy system. Generally, the controller has a fault indicator, and the user needs to determine the fault according to the controller manual. If this part fails, it can only be replaced directly.